CHINO 千野 全系sensor产品

CHINO 千野 全系sensor产品

型号︰IR-HI

品牌︰CHINO

原产地︰日本

单价︰-

最少订量︰-

现在查询

产品描述

Models

Types/Distance factors

IR-AHS For medium/high temperature (100)
IR-AHU For high temperature (250)
IR-AHT For low temperature (40)
Models Type
IR-HI Single-color type medium temperature
IR-HS Single-color type high temperature
IR-HQH High functional type (2-color type + single-color wide range type)
IR-VXG1E Data logging software package

Models

Features

IR-TA Standard type
IR-TAF Simple function
IR-TAP with memory function
 
Model     IR-TE
Model     TP-L0260EN
Models Types
Low temperature IR-SAB
Medium temperature IR-SAI
High temperature IR-SAS
Two-color type IR-SAH
Models Type
IR-CAI For medium temperature
IR-CAS For high temperature
IR-CAQ High functional type
IR-CAB Low temperature/long spectral response
IR-CAE Low short/short spectral response
IR-CAP For low/medium temperature
IR-CAW Ultra-wide type
IR-CAN For polyester film
IR-CAM For polyethylene film
IR-CAR For furnace inside
IR-CAG For glass
IR-CAT For silicone
IR-CAU For gallium arsenide
Models Types Range Response D/L Accuracy Wavelength
IR-BAT1A General type Standard 0-300°C 100ms phi40/500mm Less than 300°C:
±3°C
300°C or higher:
±1% of measured value
(at epsilon = 1.0 and reference operating condition)
8 to 14µm
IR-BAT1B 0-600°C
IR-BAT2A Small target/
Short distance
0-300°C phi5/80mm
IR-BATSA Small target/ 0-300°C phi40/1000mm
IR-BATSB Long distance 0-600°C
IR-BAT1M High-speed type Standard 0-300°C 50ms phi40/500mm
IR-BAT1P 0-600°C
IR-BAT2M Small target/
Short distance
0-300°C phi5/80mm
IR-BATSM Small target/
Long distance
0-300°C phi40/1000mm
IR-BATSP 0-600°C
IR-BAXG1 Application type Glass 100-400°C 1s phi20/150mm ±4°C 4.6 to 5.2µm
IR-BAXL1 Lamp anneal 400-1300°C 1s phi40/500mm 1% 3.43µm half-band width 120nm
IR-BAXF1 Polyethylene 80-250°C 1s phi40/500mm ±4°C
IR-BAXF2 Polyester 50-150°C 1s phi40/500mm ±4°C 7.6 to 8.4µm
IR-BAXH1 Burning gas 500-1300°C 10s phi100/1000mm 1.5% 4.3µm
Elements Models
Cooling type PbS IR-FAC
InGaAs IR-FAI
Si IR-FAS
Hybrid element IR-FAQH
Measuring diameter/measuring distance Models
phi1mm at 100mm IR-FL0
phi12mm at 1000mm IR-FL1
phi5mm at 500mm IR-FL2
phi2mm at 200mm IR-FL3
phi4mm at 200mm IR-FL4
phi5mm at 150mm IR-FL5
phi20mm at 600mm IR-FL6
phi8mm at 1000mm IR-FL8

Models

Measuring ranges

Outputs

Standard ranges
Expanded ranges
IR-SS1
400 to 600°C*, 500 to 750°C*
400 to 700°C*, 500 to 950°C*

0 to 1mADC (preamplifier output)

IR-SS2
600 to 900°C*
600 to 1200°C*
Standard range: 0 to 20mADC
Expanded range: 0 to 100mV DC
(output resistance: less than 1k)
700 to 1100°C, 1000 to 1600°C, 800 to 1200°C, 1200 to 2000°C, 900 to 1400°C
700 to 1400°C, 1000 to 2200°C, 800 to 1700°C, 900 to 1900°C
IR-SS3
1000 to 1600°C
1000 to 2200°C
0 to 1mADC (preamplifier output)
1200 to 2000°C
--
0 to 20mADC
(output resistance: less than 1k)
IR-SS4
800 to 1200°C
800 to 1700°C
0 to 1mADC (preamplifier output)
1000 to 1600°C, 1200 to 2000°C
1000 to 2200°C
Standard range: 0 to 20mADC
Expanded range: 0 to 100mV DC
(output resistance: less than 1k)
IR-SB1
600 to 900°C*
600 to 1200°C*
0 to 1mADC (preamplifier output)
700 to 1100°C, 1000 to 1600°C, 800 to 1200°C, 1200 to 2000°C, 900 to 1400°C
700 to 1400°C, 1000 to 2200°C, 800 to 1700°C, 900 to 1900°C
Standard range: 0 to 20mADC
Expanded range: 0 to 100mV DC
(output resistance: less than 1k)